<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-21 05-53-15
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 49 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 3.0 kHz -84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 67 kHz 19080 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,3 dBr 5,69 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 67 kHz MIN: 11 kHz % above 76 kHz: 0,0000 Acquired: 2026/01/21 5.52.10 Total samples: 19080 Equivalent time: 0:15:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000 4000
FM Scope MAX: 6,6 dBr MIN: 4,3 dBr AVE: 5,69 dBr % above 12,2 dBr: 0,0 Last value: 6,0 dBr (2026/01/21 5.52.09) 05.38 05.40 05.42 05.44 05.46 05.48 05.50 05.52 0 2 4 6 Pm [dBr]